IDR Integrated Digital ORP Sensor
The IDR Integrated Digital ORP Sensor uses a platinum electrode as the indicating electrode and a saturated calomel electrode as the reference. Together with the water sample, they form a galvanic cell. The oxidation-reduction potential is measured by an electronic millivoltmeter or a general-purpose pH meter, indicating the potential of the platinum electrode relative to the reference electrode. This value is then converted to an ORP value relative to the Standard Hydrogen Electrode (SHE) for final reporting.
Key words:
Classification:
- 产品描述
- Product Features
- Performance Index
- Field Application
-
<strong>Operating Principle</strong><br>
<br>
The IDR Integrated Digital ORP Sensor uses a platinum electrode as the indicating electrode and a saturated calomel electrode as the reference. Together with the water sample, they form a galvanic cell. The oxidation-reduction potential is measured by an electronic millivoltmeter or a general-purpose pH meter, indicating the potential of the platinum electrode relative to the reference electrode. This value is then converted to an ORP value relative to the Standard Hydrogen Electrode (SHE) for final reporting.<br>
<br> -
- High-impedance differential input suitable for a wide range of applications
- Digitized sensor design significantly enhances anti-interference capability
- Long-distance cabling up to several hundred meters without compromising measurement accuracy
-
Parameters
Details
Measurement Method
Glass Electrode Method
Measuring Range
-2000 mV to 2000 mV
Accuracy
Electronic unit: ±1 mV; Based on ORP standard solution: ±20 mV or ±1% FS (whichever is greater)
Repeatability
±20 mV or ±1% FS
Response Time
≤60 s
Resolution
0.3 mV
Drift
±20 mV or ±1% FS
Temperature Range
0–60°C (non-freezing)
Protection Rating
IP68
Operating Pressure
0–4 bar
Communication
RS485 / MODBUS Protocol
Power Supply
9–28 V
Dimensions
Ø40.5 × 260 mm
Material
316L Stainless Steel
Related Information
Contact us
Tengine is ready to help with quotes, technical issues, and all your questions. Simply fill out our form for a prompt response.
*Please ensure all information is accurately provided to enable us to respond to you promptly.
Tengine Innovation (Beijing) Instruments Inc.
Email: contact@tengine.com.cn
WhatsApp: +86 133 3109 8301
Address: Floor 6, Building 8, Yard 1,
Nongda South Road, Haidian District, Beijing
Copyright©2022 Tengine Innovation (Beijing) Instruments Inc.
Copyright©2022 Tengine Innovation
(Beijing) Instruments Inc.