TLD Electromagnetic Flow Meter
Application Areas:
Water and sewage treatment: inlet pipeline, outlet pipeline, sludge pipeline, etc
Key words:
Classification:
- 产品描述
- Product Features
- Performance Index
- Field Application
-
电磁流量计工作原理是基于法拉第电磁感应定律。即:导电液体在磁场中作切割磁力线运动时,在垂直于流速向量和磁场向量的方向上就会产生感应电动势,感应电动势与流量成正比,经过处理运算后,进行瞬时流量和累积流量的计量。
应用领域:
• 水及污水处理:进水管路、出水管路、污泥管路等
-
- 4-electrode measurement system: Measuring electrode, reference electrode, and empty pipe detection electrode.
- No moving parts or pressure loss in the measuring tube.
- Measurement results are independent of physical parameters such as liquid density, viscosity, temperature, pressure, and conductivity (not less than 5 μS/cm).
- Bidirectional measurement system with three built-in calculators: forward total, reverse total, and difference total.
- Available with different linings and electrode materials for excellent wear resistance or corrosion resistance.
- Unique anti-interference filter circuit and processor ensure stable output.
- Fast response speed with multi-range settings.
- Highly integrated converter with multiple functions, including fault alarms, self-diagnostics, and low-signal cut-off.
- Adjustable pulse output width.
- Equipped with a grounding electrode.
- Rich and vivid LCD display shows extensive information, including instantaneous flow and cumulative flow. The measurement system is designed with vibration and electromagnetic interference resistance.
- Optional communication protocols: HART, RS485 (MODBUS), Profibus DP, and more.
-
Measurement Performance
Nominal Diameter
DN10DN2000
Measuring Range
0.510m/s
Accuracy
±0.5% FS
Repeatability
±0.1%
Calibration
Factory calibrated
Display
LCD
Damping Time
0.5~60 seconds (can be selected with 1-second increments)
Calibration Method
Zero and span calibration using a standard signal source.
Power-off Protection
Parameters are stored in non-volatile memory and remain saved until power is restored.
Output
Digital Communication
RS485, RS232
Pulse Output
Maximum pulse output can reach 5000 cp/s;
Pulse equivalent: 0.001L1.0m³/cp
Pulse Width: Automatically set to 20ms or square wave
Communication Output
MODBUS RTU protocol
Analog Output
Isolated 420mA
Power Supply
AC Power
220VAC ±10%, 50Hz
DC Power
24VDC ±10%
Physical Performance
Housing
Cast aluminum
Electrode Material
316L stainless steel; Hastelloy B (HB); Hastelloy C (HC); Titanium (Ti); Tantalum (Ta);
Platinum-Iridium alloy; Tungsten carbide
Lining Material
Neoprene rubber; Polyurethane rubber; PTFE (polytetrafluoroethylene);
F46 (perfluorinated ethylene-propylene)
Connection Type
Flanged connection; Flanged clamp
Nominal Pressure
DN10-DN250 ≤ 1.6MPa
DN300-DN1000 ≤ 1.0MPa
DN1200 and above ≤ 0.6MPa
(Above values are the default pressure;other specifications and standards can be provided as per user requirements)
Environmental Performance
Protection Class
Transmitter: IP65;
Sensor: IP65, IP68 (customizable)
Temperature
Transmitter: -25-60℃;
Sensor: -25-60℃
Relative Humidity
5~95% RH
Related Information
Contact us
Tengine is ready to help with quotes, technical issues, and all your questions. Simply fill out our form for a prompt response.
*Please ensure all information is accurately provided to enable us to respond to you promptly.
Tengine Innovation (Beijing) Instruments Inc.
Email: contact@tengine.com.cn
WhatsApp: +86 133 3109 8301
Address: Floor 6, Building 8, Yard 1,
Nongda South Road, Haidian District, Beijing
Copyright©2022 Tengine Innovation (Beijing) Instruments Inc.